WEPEA004 | Large Vacuum Intervention to Install New BPMs and Radiation Absorbers in the LNLS Electron Storage Ring | 2475 |
|
||
In the beginning of 2008 an upgrade of the beam position monitors (BPMs) of the Brazilian Synchrotron Light Source (LNLS) electron storage ring was decided and scheduled as part of the continuous effort to improve the electron beam orbit stability. The objective was to replace most of the 24 BPMs installed in the storage ring and install new radiation absorbers inside the vacuum chamber. The original stripline BPMs were sensitive to temperature changes in the vacuum chamber. Heat, which induced mechanical stress in the striplines, could lead to fluctuations in the position readings thereby disturbing the orbit stability. The problem affected differently the BPMs. Although not a great issue during a typical user shift, the perturbations could pose some problems for the most sensitive experiments. One third of the BPMs were replaced in October 2008 and the remaining in October 2009. Thus, this large vacuum intervention aimed at improving the thermal and mechanical stability of the electron beam orbit measurement system. Finally, it will be presented the main changes made in the vacuum chambers and a survey of the evolution of the vacuum system after both interventions. |
||
THPEB041 | Status of the 476 MHz 50 kW Solid State Amplifier for the LNLS Storage Ring | 3972 |
|
||
In November 2010, LNLS plans to replace the two 50 kW UHF klystron valves which currently provides power to the RF cavities installed in the storage ring. Thanks to a close collaboration with the Syncrotron Soleil started in 1999, LNLS adapted the characteristics of the French project to 476 MHz. The choice of the transistor, the design of the combiners and details on power supplies will be reported, as well as the power tests performed with the two amplifiers using a resistive load. |
||
THPEB042 | Development of Diffusion Bonding Joints between Oxgen Free Copper and AISI 316L Stainless Steel for Accelerator Components | 3975 |
|
||
Diffusion bonding is a welding process where the main mechanism responsible for the union of the materials is the interdiffusion of atoms across the joint surface, even in solid state. The objective of the present work is to produce bonded joints that could be used in vacuum components for particle accelerator. Is this work was produced a welding joint between two dissimilar materials: oxygen free copper and AISI 316 L stainless steel. Each sample was bonded in vacuum (10-5mbar) at a temperature range between 800 and 900°C, pressure of 12MPa and holding times between 30 and 60min. Optical microscopy, scanning electron microscopy, mechanical testing and helium leak test were used to study the bond quality. The images obtained by optical and electron microscopy revealed good quality interfaces without the presence of defects and pores. All samples are tested through the helium leak test and were approved. The results indicate great potential to use this process in the manufacturing of components suitable for ultra high vacuum, for application in the design of new LNLS storage ring. |