Paper | Title | Page |
---|---|---|
MOPD067 | Status of the 2 MeV Electron Cooler for COSY/ HESR | 843 |
|
||
The 2 MeV electron cooling system for COSY-Jülich was proposed to further boost the luminosity even in presence of strong heating effects of high-density internal targets. The project is funded since mid 2009. Manufacturing of the cooler components has already begun. The space required for the 2 MeV cooler is being made available in the COSY ring. The design and construction of the cooler is accomplished in cooperation with the Budker Institute of Nuclear Physics in Novosibirsk, Russia. The 2 MeV cooler is also well suited in the start up phase of the High Energy Storage Ring (HESR) at FAIR in Darmstadt. It can be used for beam cooling at injection energy and is intended to test new features of the high energy electron cooler for HESR. Two new prototypes of the modular high voltage system were developed, one consisting of gas turbines the other based on inductance-coupled cascade generators. The new 2 MeV electron cooler is described in detail and tests of components are reported. |
||
MOPD070 | Numerical Study on Simultaneous Use of Stochastic Cooling and Electron Cooling with Internal Target at COSY | 852 |
|
||
A small momentum spread of proton beam has to be realized and kept in a storage ring during an experiment with a dense internal target such as a pellet target. A stochastic cooling alone does not compensate the mean energy loss by the internal target. Barrier bucket operation will cooperate effectively the energy loss. In addition, the further small momentum spread can be realized with use of an electron cooling. In the present study, the simulation results on the simultaneous use of stochastic cooling and electron cooling at COSY are presented. |
||
MOPD093 | Nondestructive Beam Instrumentation and Electron Cooling Beam Studies at COSY | 921 |
|
||
To study electron cooling in a synchrotron nondestructive methods only are suitable. The ionization profile monitor (IPM) delivers real-time data in both transverse planes allowing detailed analysis of beam profile evolution in COSY. First attempts to use scintillation of residual gas (SPM) to measure beam profiles were very promising. Beam diagnostics based on recombination is usually used to optimize electron cooling of protons (H0-diagnostics). However, it is not available when cooling antiprotons. So the IPM and possibly the SPM are vital for electron cooling optimization in the HESR ring. The new beam instrumentation at COSY is introduced and its relevance for the new 2 MeV electron cooler project and the HESR are discussed. Results of beam studies performed during electron cooling beam times at COSY are presented. |