MOPE051 | Development and Test Benchmarks of the Beam Position Monitor Series for the TBL line of the CTF3 at CERN | 1086 |
|
||
A set of 16 Inductive Pick-Ups (IPU) for Beam Position Monitoring (BPM) with its associated electronics were designed, constructed and characterized at IFIC for the Test Beam Line (TBL) of the 3rd CLIC Test Facility (CTF3) at CERN. In October 2009 the full set of IPUs, (BPS) was successfully installed in the TBL line. In this paper, we describe the prototyping and series production phases of the BPSs development, focusing in the implementation and the results analysis derived from their characterization tests. Two special test benches were designed and built to perform the characterization tests at low and high frequencies. The low frequency set up based on a wire-method test bench for emulating the beam position variations helped us to determine the BPS performance parameters at beam pulse time scale from 100μs/10kHz to 10ns/100MHz. On the other hand, the high frequency test setup, based on an adapted coaxial transmission line, was dedicated to obtain the BPS longitudinal coupling impedance at the beam microbunches time scale (83ps/12GHz). Furthermore, we also present the first beam performance tests made in the TBL line. |