A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Chang, C.-H.

Paper Title Page
MOPEB020 Measurement of Accelerator Lattice Magnet Prototypes for TPS Storage Ring 319
 
  • F.-Y. Lin, C.-H. Chang, H.-H. Chen, J.C. Huang, M.-H. Huang, C.-S. Hwang, J.C. Jan, C.Y. Kuo, C.-S. Yang
    NSRRC, Hsinchu
 
 

Taiwan Photon Source (TPS) is a new third generation synchrotron storage ring with energy 3 GeV, which consists of 24 double-bend cells and its circumference is 518.4 m. Various accelerator lattice magnets which consist of 48 bending magnets, 240 quadrupoles and 168 multifunction sextupole magnets. All magnets pole profiles, edge shim and magnet end chamfer were designed in TOSCA and RADIA magnetic computation code. In order to verify the magnetic field quality of computation code, prototype magnets have been manufactured in this year. Two measurement systems, hall probe and rotating coils, were used for magnetic field mapping. This paper presents magnetic field mapping results of prototype magnets and compared with original magnetic circuit designs.

 
MOPEB021 Measurement of Field Inaccuracy and Shim Simulation of a 130-Pole Superconducting Undolator 322
 
  • J.C. Jan, C.-H. Chang, C.-S. Hwang, F.-Y. Lin
    NSRRC, Hsinchu
 
 

A magnet array of superconducting undulator SU15, with 130 poles and length 0.98 m, was constructed, and the field measurement and training are also performed at National Synchrotron Radiation Research Center (NSRRC). The NbTi wires were excited to 1.36 T @ 497 A after 28 times quench. A cryogenic Hall probe (length 2500 mm) was used to characterize the distribution of the magnetic field of magnet arrays in the 5.6-mm magnetic gap. The measurement region of the cryogenic Hall probe is greater than 1200 mm in the vertical dewar. The length shrinkage or expansion of the Hall probe depends on the thermal variation at both ends of the Hall probe. The length of the Hall probe will be evaluated in the field measurement region. The reproducibility of the measurement system was verified in the same experiment. A field shimming method involving a trim iron piece was used to correct for deviations of the magnetic field. This paper discusses the measurement accuracy in the cryogenic Hall probe system and presents results of the field shimming.

 
MOPEB022 Magnet Field Crosstalk Effect of TPS Storage Ring Magnets 325
 
  • C.Y. Kuo, C.-H. Chang, C.-S. Hwang
    NSRRC, Hsinchu
 
 

The free space between magnets of TPS storage ring is very tight, especially the space between quadrupole and sextupole magnets. The minimum space between the yoke of quadrupole and sextupole is about 150mm, and the space between coils is only 10mm. In this case, the significant magnetic field distortions could have an impact on the performance of machine. Two magnets simulation compare to the individual magnet were performed in TOSCA 3D model. The crosstalk effect shows that the sextupole component increases from 0.0004% to 0.04% in the quadrupole magnet and the quadrupole component increases from 0.0008% to 0.06% in the sextupole magnet. We discuss this crosstalk effect and how to decrease the effect with appropriate shielding.

 
TUPEC033 Effectiveness of a Shielding Cabinet on the Storage-Ring Septum Magnet of Taiwan Light Source 1793
 
  • J.C. Huang, C.-H. Chang, C.-S. Hwang, C.Y. Kuo, F.-Y. Lin, C.-S. Yang
    NSRRC, Hsinchu
 
 

Pulsed magnet system of Taiwan Photon source(TPS) requires a very low stray field to avoid parasitic magnetic field into the stored beam. The stray field from storage ring(SR) injection septum is required to be less than 0.2 Gauss. The most common method to protect parasitic magnetic field is to use high permeability and conductivity material, such as a Mu-metal. A 1.2 ms half-sine wave pulse of up to 8280A current peak are supply to a septum and would result in eddy current loss in magnet and conductor current diffusion during the rapid charging on magnet. Moreover, competition between eddy current loss and magnetic permeability would lead to a complex phenomena inside the mumetal shielding cabinet and shielding performance. In this study, the magnetic shielding performance of a shielding cabinet was examined in different shielding cabinet geometry and thickness. The results were calculated in Opera software and show that there is a significant suppression of SR septum stray field when round shielding cabinet is in use.

 
WEPD042 Design and Development of an Elliptically Polarized Undulator of Length 3.5 m for TPS 3183
 
  • C. H. Chang, C.-H. Chang, H.-H. Chen, J.C. Huang, M.-H. Huang, C.-S. Hwang, F.-Y. Lin, C.M. Wu
    NSRRC, Hsinchu
 
 

An elliptically polarized undulator of length 3.5 m and period length 48 mm (EPU48) is designed to fulfil experiments on spin-polarized PES and inelastic scattering at the Taiwan Photon Source (TPS). EPU48 would be used to produce variously polarized light in the soft X-ray spectral domain 0.4-1.5 keV. To achieve efficient mechanical performance and a high quality of photon source, a new manufacturing method by casting is adopted to fabricate a key component of the carriage of the undulator at National Synchrotron Radiation Research Center (NSRRC). We expect this approach to bestow advantages of decreased assembly error, increased rigidity and highly precise properties. Here we describe details of the design of the magnetic circuit and the mechanical design of the EPU48 based on this new concept of engineering construction.