A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Boorman, G.E.

Paper Title Page
MOPE069 A 2-D Laser-wire Scanner at PETRA-III 1137
 
  • T. Aumeyr, G.A. Blair, S.T. Boogert, G.E. Boorman, A. Bosco
    JAI, Egham, Surrey
  • K. Balewski, E. Elsen, V. Gharibyan, G. Kube, S. Schreiber, K. Wittenburg
    DESY, Hamburg
 
 

The PETRA-III Laser-wire, a Compton scattering beam size measurement system at DESY, uses an automated mirror to scan a Q-switched laser across the electron beam and is developed from the system previously operated at PETRA-II. This paper reports on recent upgrades of the optics, vacuum vessel and data acquisition. First beam profile measurements are also presented.

 
MOPE070 Cavity Beam Position Monitor System for ATF2 1140
 
  • S.T. Boogert, G.E. Boorman, C. Swinson
    JAI, Oxford
  • R. Ainsworth, S. Molloy
    Royal Holloway, University of London, Surrey
  • A.S. Aryshev, Y. Honda, T. Tauchi, N. Terunuma, J. Urakawa
    KEK, Ibaraki
  • J.C. Frisch, J. May, D.J. McCormick, J. Nelson, T.J. Smith, G.R. White, M. Woodley
    SLAC, Menlo Park, California
  • A. Heo, E.-S. Kim, H.-S. Kim, Y.I. Kim
    Kyungpook National University, Daegu
  • A. Lyapin
    UCL, London
  • H.K. Park
    KNU, Deagu
  • M.C. Ross
    Fermilab, Batavia
  • S. Shin
    PLS, Pohang
 
 

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (BPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance.

 
MOPE071 Coherent Diffraction Radiation Longitudinal Beam Profile Monitor for CTF3 1143
 
  • M. Micheler, G.A. Blair, G.E. Boorman, V. Karataev, K. Lekomtsev
    JAI, Egham, Surrey
  • R. Corsini, A.E. Dabrowski, T. Lefèvre
    CERN, Geneva
  • S. Molloy
    Royal Holloway, University of London, Surrey
 
 

A setup for the investigation of Coherent Diffraction Radiation (CDR) from a conducting screen as a tool for non-invasive longitudinal electron beam profile diagnostics has been designed and installed in the Combiner Ring Measurement (CRM) line of the CLIC Test Facility (CTF3, CERN). In this report the status of the monitor development and results on the interferometric measurements of CDR spectra are presented. The CDR signal correlation with an RF pickup and a streak camera is reported. The future plans for the system improvements are also discussed.