WEPEB047 Observation and Improvement of the Long Term Beam Stability using X-ray Beam Position Monitors at DLS 2797
 
  • C. Bloomer, G. Rehm, C.A. Thomas
    Diamond, Oxfordshire
 
 

We present our observations of the medium term and long term stability of the photon beams at Diamond Light Source. Drift of the Electron Beam Position Monitors results in real X-ray beam movements, observed by both Front End X-ray Beam Position Monitors and beamline scintillator screens on some beamlines. We discuss how we are using these diagnostics tools to measure and characterise the drift. Medium term movements related to top-up cycles are seen, believed to be caused by changes to single bunch charge, and the long term drift of the electron beam position over several days and weeks is examined. A slow feedback system using X-ray Beam Position Monitors has been shown to successfully correct this drift. The results of these trials are presented.