Paper |
Title |
Page |
MOPGF117 |
The Control System for Trim-Coil Relay-Selectors in J-PARC MR |
353 |
|
- K.C. Sato, N. Kamikubota, N. Yamamoto
J-PARC, KEK & JAEA, Ibaraki-ken, Japan
- S. Igarashi
KEK, Ibaraki, Japan
- S.Y. Yoshida
Kanto Information Service (KIS), Accelerator Group, Ibaraki, Japan
|
|
|
In J-PARC main ring, each of the main magnets (Dipole, Quadrupole, and Sextupole) has a trim-coil. The basic aim of trim-coil is to correct small deviation of each magnetic field. In addition, we have used them for other purposes, for example: (1) in Beam-Based-Alingnment studies, (2) as flux monitors, and (3) to make a short-circuit to reduce ripples of magnetic field. At a moment, trim-coils can be used for only one purpose. Relay-switches were introduced to change trim-coil connection to a device, which corresponds to the selected purpose. When the purpose is switched, 1,200 on-site relays have to be changed manually, distributed in three buildings. Thus, a control system for trim-coil relay-selectors was developed in winter, 2014-2015. EPICS tools and environment are used to develop the system. The system comprises PLC I/O modules with controller running EPICS on Linux. The system will be in operation after March, 2015. By using the system, a much easier switching of relay-switches than before, is expected.
|
|
|