Paper |
Title |
Page |
MOPGF160 |
ARIEL Control System at TRIUMF - Status Update |
460 |
|
- R.B. Nussbaumer, D. Dale, K. Ezawa, K. Fong, H. Hui, R. Iranmanesh, J. Kavarskas, D.B. Morris, J.J. Pon, S. Rapaz, J.E. Richards, M. Rowe, T.M. Tateyama, E. Tikhomolov, G. Waters, P.J. Yogendran
TRIUMF, Canada's National Laboratory for Particle and Nuclear Physics, Vancouver, Canada
|
|
|
The Advanced Rare Isotope & Electron Linac (ARIEL) facility at TRIUMF has now reached completion of the first phase of construction; the Electron Linac. A commissioning control system has been built and used to commission the electron e-gun and two stages of SRF acceleration. Numerous controls subsystems have been deployed including beamlines, vacuum systems, beamline diagnostics, machine protect system interfaces, LLRF, HPRF, and cryogenics. This paper describes some of the challenges and solutions that were encountered, and describes the scope of the project to date. An evaluation of some techniques that had been proposed and described at ICALEPCS 2013 are included.
|
|
|
Poster MOPGF160 [1.394 MB]
|
|
Export • |
reference for this paper using
※ BibTeX,
※ LaTeX,
※ Text/Word,
※ RIS,
※ EndNote (xml)
|
|
|
WEPGF154 |
Visualization of Interlocks with EPICS Database and EDM Embedded Windows |
1066 |
|
- E. Tikhomolov
TRIUMF, Canada's National Laboratory for Particle and Nuclear Physics, Vancouver, Canada
|
|
|
The control system for TRIUMF's upgraded secondary beam line M20 was implemented by using a PLC and one of many EPICS IOCs running on a multi-core Dell server. Running the IOC on a powerful machine rather than on a small dedicated computer has a number of advantages such as fast code execution and the availability of a large amount of memory. A large EPICS database can be loaded into the IOC and used for visualization of the interlocks implemented in the PLC. The information about interlock status registers, text messages, and the names of control and interlock panels are entered into a relational database by using a web browser. Top-level EPICS schematics are generated from the relational database. For visualization the embedded windows available in the Extensible Display Manager (EDM) are the EPICS clients, which retrieve interlock status information from the EPICS database. A set of interlock panels is the library, which can be used to show any chains of interlocks. If necessary, a new interlock panel can be created by using the visualization tools provided with EDM. This solution, in use for more than 3 years, has proven to be reliable and very flexible.
|
|
|