Paper |
Title |
Page |
TUPPC120 |
LHC Collimator Alignment Operational Tool |
860 |
|
- G. Valentino, R.W. Aßmann, S. Redaelli
CERN, Geneva, Switzerland
- N.J. Sammut
University of Malta, Information and Communication Technology, Msida, Malta
|
|
|
Beam-based LHC collimator alignment is necessary to determine the beam centers and beam sizes at the collimator locations for various machine configurations. Fast and automatic alignment is provided through an operational tool has been developed for use in the CERN Control Center, which is described in this paper. The tool is implemented as a Java application, and acquires beam loss and collimator position data from the hardware through a middleware layer. The user interface is designed to allow for a quick transition from application start up, to selecting the required collimators for alignment and configuring the alignment parameters. The measured beam centers and sizes are then logged and displayed in different forms to help the user set up the system.
|
|
|
Poster TUPPC120 [2.464 MB]
|
|
|
THCOCB03 |
Fast Automatic Beam-based Alignment of the LHC Collimation System |
1430 |
|
- G. Valentino, R.W. Aßmann, R. Bruce, S. Jackson, S. Redaelli, B. Salvachua, D. Wollmann, C. Zamantzas
CERN, Geneva, Switzerland
- N.J. Sammut
University of Malta, Information and Communication Technology, Msida, Malta
|
|
|
Maximum beam cleaning efficiency and LHC machine protection is provided when the collimator jaws are properly adjusted at well-defined distances from the circulating beams. The required settings for different locations around the 27 km long LHC rings are determined through beam-based collimator alignment, which uses feedback from Beam Loss Monitoring (BLM) system. After the first experience with beam, a systematic automation of the alignment procedure was performed. This paper gives an overview of the algorithms developed to speed up the alignment and reduce human errors. The experience accumulated in four years of operation, from 2010 to 2013 is reviewed.
|
|
|
Slides THCOCB03 [13.293 MB]
|
|
|
TUPPC111 |
Online Status and Settings Monitoring for the LHC Collimators |
836 |
|
- G. Valentino
University of Malta, Information and Communication Technology, Msida, Malta
- R.W. Aßmann, D. Jacquet, S. Redaelli, E. Veyrunes
CERN, Geneva, Switzerland
|
|
|
The Large Hadron Collider is equipped with 100 movable collimators. The LHC collimator control system is responsible for the accurate synchronization of around 400 axes of motion at the microsecond level, and with the precision of a few micrometres. The status and settings of the collimators can be monitored by three displays in the CERN Control Center, each providing a different viewpoint onto the system and a different level of abstraction, such as the positions in mm or beam size units. Any errors and warnings are also displayed. In this paper, the display operation is described, as well as the interaction that occurs when an operator is required to identify and understand an error in the collimator settings.
|
|
|
Poster TUPPC111 [2.260 MB]
|
|
|