Author: Shirokov, A.V.
Paper Title Page
THPPC050 Upgrade System of Vacuum Monitoring of Synchrotron Radiation Sources of National Research Centre Kurchatov Institute 1183
 
  • N.I. Moseiko, V. Dombrovsky, Y.V. Efimov, V. Korchuganov, Y.V. Krylov, D.G. Odintsov
    NRC, Moscow, Russia
  • L.A. Moseiko, A.V. Shirokov
    RRC, Moscow, Russia
  • B.I. Semenov
    RRC KI, Moscow, Russia
 
  Modernization project of the vacuum system of the synchrotron radiation source at the National Research Centre Kurchatov Institute (NRC KI) has been designed and implemented. It includes transition to the new high-voltage power sources for NMD and PVIG–0.25/630 pumps. The system is controlled via CAN-bus, and the vacuum is controlled by measuring pump currents in a range of 0.0001–10 mA. Status visualization, data collection and data storage is implemented on Sitect SCADA 7.2 Server and SCADA Historian Server. The system ensures a vacuum of 10–7 Pa. The efficiency and reliability of the vacuum system is increased by this work, making it possible to improve the main parameters of the SR source.