Author: Zhou, W.M.
Paper Title Page
TUPB036 Progress of Cavity Beam Position Monitor at SXFEL 399
 
  • L.W. Lai, Z.C. Chen, Y.B. Leng, Y.B. Yan, L.Y. Yu, R.X. Yuan, W.M. Zhou
    SSRF, Shanghai, People's Republic of China
 
  Shanghai Soft X-ray FEL Test Facility (SXFEL) has started the infrastructure construction in 2015. All beam diagnostic systems are under processing and measurement, including C-band Low-Q cavity BPMs. This paper presents the progress of the cavity BPM system, including design and the measurements on a lab platform. Measurements shown that the cavity BPM frequency is 4.7GHz±8MHz, and the complete test platform verify that the cavity BPM system, which including signal processing electronics can work as expected.
* Work supported by National Natural Science Foundation (No. 11305253, 11375255)
 
Export • reference for this paper to ※ BibTeX, ※ LaTeX, ※ Text, ※ RIS/RefMan, ※ EndNote (xml)