Author: Sirvent Blasco, J.L.
Paper Title Page
TUPB053 A High Dynamic Range Diamond Detector Readout System for the CERN Beam Wire Scanners Program 441
 
  • J.L. Sirvent Blasco, B. Dehning, J. Emery
    CERN, Geneva, Switzerland
  • A. Dieguez
    UB, Barcelona, Spain
 
  A secondary particle shower acquisition system is under design for the upgrade of CERN's beam wire scanners. The system needs to be capable of performing bunch-by-bunch synchronous measurements with an integration time of 25 ns and to cope with signal variations of up to 6 orders of magnitude. The whole dynamic range should be covered by the acquisition system with a single configuration and should have no tuneable parameters. The secondary particles are detected using a polycrystalline diamond detector with the signal digitization performed nearby with a custom front-end system, designed to resist a total ionising radiation dose up to 1 kGy in 10 years. The digital data transmission, front-end synchronization and control are performed through a bi-directional optical link operating at 4.8 Gbps using CERN's GBT protocol. For the digitization, two radiation tolerant integrator ASICs (ICECAL and QIE10) are under study.  
poster icon Poster TUPB053 [1.323 MB]  