Paper |
Title |
Page |
TUPA07 |
BPM Selection for Beam Current Monitoring in SSRF |
341 |
|
- Z.C. Chen, Y.B. Leng, Y.B. Yan
SSRF, Shanghai, People's Republic of China
|
|
|
Although Direct Current Current Transformer (DCCT) is the general solution of beam current monitor, Beam Position Monitor (BPM) sum signals may still surpass it in some aspects such as the faster data rate and higher resolution in low current situations. Nevertheless, an additional monitor should be harmless. Meanwhile, the DCCTs in the storage ring of Shanghai Synchrotron Radiation Facility (SSRF) have been suffering from various noise and the signals from the BPMs could be an aid to provide the beam current more accurately. There're 140 BPMs in the storage ring in SSRF but not all of them are suitable for this particular usage. This article focuses on the methods used here to dynamicly choose the BPMs that meet the criteria.
|
|
|
TUPA11 |
SSRF BPM System Optimization and Upgrade |
355 |
|
- Y.B. Yan, Y.B. Leng
SSRF, Shanghai, People's Republic of China
- L.Y. Yu, W.M. Zhou
SINAP, Shanghai, People's Republic of China
|
|
|
The beam position monitor (BPM) system at SSRF was fully equipped with Libera Electrons. It have operated steadily for nearly five years. During the summer shutdown of 2012 more than 50 Libera Electrons were upgraded to Libera Brilliance which are used mainly for fast obit feedback system. The software of whole system is upgraded from 1.42 to 2.07. Some other hardware and software optimizations are carried out. After this upgrade, the stability and performance have been improved significantly. This paper introduces the details of the optimization and upgrade.
|
|
|