Author: Lee, D.
Paper Title Page
MOPA33 Image Profile Diagnostics Solution for the Taiwan Photon Source 125
 
  • C.Y. Liao, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, K.H. Hu, C.H. Kuo, D. Lee, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  TPS (Taiwan Photo Source) is a third generation 3 GeV synchrotron light facility, featuring ultra-high photon brightness with extremely low emittance which will be a state-of-the-art synchrotron radiation facility and is being in construction at National Synchrotron Radiation Research Center (NSRRC) campus. Beam image profile and its analysis play an important role in beam diagnostics of a particle accelerator system. However, due to the CCD image collection devices are distributed around the linac, booster, and storage ring, a distributed EPICS system based image profile diagnostics solution was proposed, which are based on GigE Vision camera with PoE support. This solution provides an easy way for cabling, and delivery adequate performance. Implementation plan for the TPS and results of prototype test at existed facility to examine functionality of hardware and software will be summarized in this report.