Author: De Santis, S.
Paper Title Page
TUPB49 Electron Cloud Density Measurements using Resonant TE Waves at CesrTA 471
 
  • J.P. Sikora, M.G. Billing, D.O. Duggins, Y. Li, D. L. Rubin, R.M. Schwartz, K.G. Sonnad
    CLASSE, Ithaca, New York, USA
  • S. De Santis
    LBNL, Berkeley, California, USA
 
  Funding: This work is supported by the US National Science Foundation PHY-0734867, PHY-1002467, and the US Department of Energy DE-FC02-08ER41538, DE-SC0006505.
The Cornell Electron Storage Ring has been reconfigured as a test accelerator (CesrTA) with beam energies ranging from 2 GeV to 5 GeV of either positrons or electrons. Research at CesrTA includes the study of the growth, decay and mitigation of electron clouds in the storage ring. Electron Cloud (EC) densities can be measured by resonantly exciting the beam-pipe with microwaves. The EC density will change beam-pipe's resonant frequency by an amount that is proportional to the local electric field squared of the standing waves. When the EC density is not uniform, it is especially important to know the standing wave pattern in order to obtain an absolute EC density measurement. We will present our current understanding of this technique in the context of new test sections of beam-pipe installed in August 2012. This will include bench measurements of standing waves in the beam-pipe, simulations of this geometry and recent EC density measurements with beam.