Author: Cheng, Y.-S.
Paper Title Page
MOPA33 Image Profile Diagnostics Solution for the Taiwan Photon Source 125
 
  • C.Y. Liao, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, K.H. Hu, C.H. Kuo, D. Lee, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  TPS (Taiwan Photo Source) is a third generation 3 GeV synchrotron light facility, featuring ultra-high photon brightness with extremely low emittance which will be a state-of-the-art synchrotron radiation facility and is being in construction at National Synchrotron Radiation Research Center (NSRRC) campus. Beam image profile and its analysis play an important role in beam diagnostics of a particle accelerator system. However, due to the CCD image collection devices are distributed around the linac, booster, and storage ring, a distributed EPICS system based image profile diagnostics solution was proposed, which are based on GigE Vision camera with PoE support. This solution provides an easy way for cabling, and delivery adequate performance. Implementation plan for the TPS and results of prototype test at existed facility to examine functionality of hardware and software will be summarized in this report.  
 
TUPA01 Diagnostics Update of the Taiwan Photon Source 324
 
  • C.H. Kuo, J. Chen, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, S.Y. Hsu, K.H. Hu, C.Y. Liao, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  Taiwan Photon Source (TPS) is a 3 GeV synchrotron light source which is being construction at campus of NSRRC. Various diagnostics are in implementation and will deploy in the future to satisfy stringent requirements of TPS for commissioning, top-up injection, and operation. These designs include beam intensity observation, trajectory and beam positions measurement, destructive profile measurement, synchrotron radiation monitors, beam loss monitors, orbit and bunch-by-bunch feedbacks, filling pattern and etc. are in final design phase. Progress of construction of the planned beam instrumentation system for the TPS will be summarized in this report.  
 
TUPA02 Modernized of the Booster Synchrotron Diagnostics in the Taiwan Light Source 329
 
  • C.H. Kuo, J. Chen, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, S.Y. Hsu, K.H. Hu, C.Y. Liao, C.Y. Wu
    NSRRC, Hsinchu, Taiwan
 
  Taiwan Light Source is an 1.5 GeV synchrotron based light source which dedicated almost 20 year ago. During several major and minor upgrades, the TLS operate in top-up mode. To provide a better operation of the injector for the TLS, several minor upgrade in diagnostics are proceed recently. Efforts of these upgrades and modifications will summary in this report.