A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Kulevoy, T.

Paper Title Page
E-06 High Current Ion Sources, Beam Diagnostics and Emittance Measurement 341
 
  • M. Cavenago, M. Comunian, E. Fagotti, M. Poggi
    INFN/LNL, Legnaro
  • T. Kulevoy, S. Petrenko
    ITEP, Moscow
 
 

Singly charged ion sources can easily surpass the 1 kW beam power, as in TRIPS (H+, 60 mA, 80 kV, now installed at LNL) or in NIO1 (H-, 130 mA distributed into 9 beamlets, 60 kV, a project of RFX and INFN-LNL). Beam diagnostic constitutes an important instrument in the high current source development. Even if calorimetric and optical beam profile monitors become possible, still a phase space plot of the beam will be the most useful tool for validation of extraction simulation and for input of subsequent beam transport optimization. Improvements in extraction beam simulations are briefly reported, and effect of space charge neutralization is discussed. Since preliminary design of the traditional two moving slit beam emittance meter show problems with slit deformations and tolerances and with secondary emission, an Allison scanner was chosen with the advantages: only one movement is needed; data acquisition is serial and signal can have an adequate suppression of secondary electrons. The design of a compact Allison scanner head is discussed in detail, showing: 1) the parameter optimization; 2) the segmented construction of electrodes. Experimental commissioning at lower power seems advisable.

 
E-05 Upgrade and Commissioning of the PIAVE-ALPI ECR Injector at LNL 336
 
  • A. Galatà, L. Bertazzo, L. Boscagli, S. Contran, A. Dainese, A. Facco, A. Lombardi, D. Maniero, M. Poggi, M. Sattin, F. Scarpa
    INFN/LNL, Legnaro
  • T. Kulevoy
    ITEP, Moscow
 
 

The positive ion injector for the PIAVE-ALPI complex consists of an ECR ion source placed on a high voltage platform. A 14.4 GHz ECRIS named Alice, designed and constructed at LNL in the early &##8216;90, reliably delivered gaseous beams to the Superconducting RFQ PIAVE for nuclear physics experiments until 2008. The requests for heavy ion beams of increased current and energy, needed to perform the experiments planned for the next years with the AGATA demonstrator, prompted us to upgrade our injector with a new ECR source capable of higher output beam currents and higher charge states. This activity started in 2008 and was completed at the beginning of 2009. A 14.5 GHz, SUPERNANOGAN type ECRIS built by Pantechnik, was installed in our refurbished high voltage platform in July 2008. The space available for maintenance in the platform was increased and a new lead shielding for X-rays has been set up. The water cooling circuits have been redesigned to deliver different fluxes and inlet pressures to the equipment mounted on the platform (plasma chamber, extraction electrodes, bending dipole and power supply). A new safety system has been implemented in order to cope with new and more demanding safety rules. A lot of attention has been paid to the optimisation of the injection line with new diagnostic devices for beam characterisation (movable slits, emittance measurement tools). Commissioning of the new source and injector with beams has started and first results will be reported.