Paper | Title | Page |
---|---|---|
WGA03 | Measurement of the Transverse Resistive Wall Impedance of a LHC Graphite Collimator at Low Frequency | 48 |
|
||
The largest contribution to the LHC transverse resistive wall impedance is given by the graphite collimators. Such a contribution is predicted by analytical calculations. A series of laboratory measurements were performed to experimentally validate the analytical results in the case of small gaps and in a low frequency regime where the skin depth becomes comparable to the collimator thickness. The measurement method consists in determining the dependence of a probe coil input impedance on the surrounding materials and was applied to sample graphite plates, stand alone LHC collimator jaws and a full collimator assembly. After reviewing the measurement procedures, problematics and stages, the results are compared to analytical predictions and numerical simulations. |
||
|