TY - CPAPER AU - Kim, S.H. AU - Cho, M.-H. AU - Jang, K.Y. AU - Kang, H.-S. AU - Kim, D.S. AU - Kim, G.H. AU - Ko, I.S. AU - Kwon, S.J. AU - Lee, H.-S. AU - Lee, S.Y. AU - Park, S.S. AU - Park, Y.J. AU - Seo, M. AU - Shin, H.S. TI - PAL XFEL Pulse Modulator System Test Results Using a High Precision CCPS J2 - Proc. of FEL2015 AB - PAL XFEL is supposed to install 51 units of the pulse modulator power supplies for a 10-GeV linear accelerator using S-band (2856 MHz) cavities. The requirements of the modulator stability really become very tight. The stability on beam voltage is required to be less than 50 ppm. In order to obtain the high precision stability from the modulator system, we have newly produced a capacitor charging power supply (CCPS) and obtained the target stability with 10 ppm (STD) accuracy from measuring PFN (Pulse Forming Network). The CCPS generates a maximum output voltage of 50 kV at average current of 2.4 A with 4 units of the CCPS. The modulator peak output capacity is 400 kV, 500 A and 7.5 us at a pulse repetition rate of 60 pps using CCPS, a modified type-E PFN, and a pulse transformer. In this paper, the test results of the modulator system will be described. PB - JACoW CY - Geneva, Switzerland SP - 89 EP - 92 KW - klystron KW - controls KW - power-supply KW - high-voltage KW - resonance DA - 2015/12 PY - 2015 SN - 978-3-95450-134-2 DO - 10.18429/JACoW-FEL2015-MOP029 UR - http://accelconf.web.cern.ch/AccelConf/FEL2015/papers/mop029.pdf ER -