A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Yocky, G.

Paper Title Page
TUOA03 FEL Gain length and Taper Measurements at LCLS 221
 
  • D.F. Ratner, A. Brachmann, F.-J. Decker, Y.T. Ding, D. Dowell, P. Emma, J.C. Frisch, A. Gilevich, G.R. Hays, P. Hering, Z. Huang, R.H. Iverson, H. Loos, A. Miahnahri, H.-D. Nuhn, J.L. Turner, J.J. Welch, W.E. White, J. Wu, D. Xiang, G. Yocky
    SLAC, Menlo Park, California
  • W.M. Fawley
    LBNL, Berkeley, California
 
 

We present experimental studies of the gain length and saturation levels from 1.5 nm to 1.5 Å for a variety of conditions at the Linac Coherent Light Source (LCLS). By disrupting the FEL process with an orbit kick, we are able to measure the X-ray intensity as a function of the undulator length. This kick method is cross-checked with the method of removing undulator sections. We measure the FEL gain length as a function of X-ray wavelength, laser-heater induced energy spread, beta function and peak electron current. We also study the X-ray intensity level and FEL-induced electron energy loss after saturation as a function of undulator K value to determine the optimal taper. The experimental results are compared to analytical formulae and simulations.

 

slides icon

Slides