TUOA03 | FEL Gain length and Taper Measurements at LCLS | 221 |
|
||
We present experimental studies of the gain length and saturation levels from 1.5 nm to 1.5 Å for a variety of conditions at the Linac Coherent Light Source (LCLS). By disrupting the FEL process with an orbit kick, we are able to measure the X-ray intensity as a function of the undulator length. This kick method is cross-checked with the method of removing undulator sections. We measure the FEL gain length as a function of X-ray wavelength, laser-heater induced energy spread, beta function and peak electron current. We also study the X-ray intensity level and FEL-induced electron energy loss after saturation as a function of undulator K value to determine the optimal taper. The experimental results are compared to analytical formulae and simulations. |
||
|