A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Tanaka, H.

Paper Title Page
TUOA02 Electron Bunch Compression with Dynamical Non-linearlity Correction for a Compact FEL 215
 
  • T. Hara, H. Tanaka, K. Togawa
    RIKEN/SPring-8, Hyogo
 
 

To realize a compact FEL facility, a high frequency accelerator is indispensable to shorten the accelerator length. Then, a high-harmonic cavity used for nonlinear correction of a beam energy chirp encounters a technological difficulty of extremely high frequency RF system. In order to overcome this difficulty, a method of over-correction is proposed. In this method, a correction cavity is installed before any bunch compressors. Since the effective frequency of the correction cavity is increased as the electron bunch length compressed, the same RF frequency as main accelerators can be used for the correction cavity.

 

slides icon

Slides

 
FROA01 High Performance SASE FEL Achieved by Stability-Oriented Accelerator System 758
 
  • H. Tanaka, T. Fukui, T. Hara, N. Hosoda, T. Inagaki, S.I. Inoue, T. Ishikawa, H. Kitamura, C. Kondo, N. Kumagai, H. Maesaka, M. Nagasono, T. Ohshima, Y. Otake, T. Sakurai, T. Shintake, K. Shirasawa, T. Tanaka, K. Togawa, K. Tono, M. Yabashi
    RIKEN/SPring-8, Hyogo
  • T. Hasegawa, Y. Kano, T. Morinaga, H. Ohashi, Y. Tajiri, S. Takahashi, S. Tanaka, T. Togashi, M. Yamaga, R. Yamamoto
    JASRI/SPring-8, Hyogo-ken
 
 

Stable SASE FEL has been routinely used for user experiments since May 2008 at the SCSS test accelerator, which was constructed to perform a proof-of-principle experiment towards realization of a compact and high performance XFEL facility. In FY2008, a beam time of 840 hr (95 days) was provided to 11 research groups with a downtime rate of ~4%, a pulse energy of ~30μJ and an intensity fluctuation of ~10% in STD. A feature of our stable operation is power-saturated SASE FEL kept over a full operation period

  1. in spite of a day-by-day operation,
  2. without a complicated beam feedback control, and
  3. without hard maintenance.
In this talk we will try to review key points much contributing to this stable SASE FEL operation from the viewpoint of accelerator design, hardware and operation together with achieved SASE FEL performance and some experimental results reflecting the FEL performance.

 

slides icon

Slides