Author: Kidera, M.
Paper Title Page
MOPOT003 Study of Potential Application of Compact ECRIS to Analytical System 46
 
  • M. Kidera
    RIKEN Nishina Center, Wako, Japan
  • S. Enomoto
    Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan
  • S. Kishi, Y. Seto
    National Research Institute of Police Science, Chiba, Japan
  • T. Nagamatsu, T. Tanaka
    Tokyo University of Science, Faculty of Engineering Division I, Tokyo, Japan
  • K. Takahashi
    RIKEN, Saitama, Japan
 
  A place of an ac­tiv­i­ty of ECR ion sources is not only ion source on a heavy ion ac­cel­er­a­tor fa­cil­i­ty. A high­ly ion­iza­tion ef­fi­cien­cy, flex­i­bil­i­ty of ion­ized sam­ple, low con­sump­tion rate in sam­ple, and non-equi­lib­ri­um ECR plas­ma, etc. that a ECR ion source have, may be need­ed in other fields at time. We have de­vel­oped sev­er­al kinds of small ECRISs that have cus­tomized for the anal­y­sis. The pur­pos­es of the anal­y­sis are, pre­cise mea­sure­ment of iso­tope ratio of a metal el­e­ment, de­tec­tion of chem­i­cal war­fare agents, and de­tec­tion of pro­duced molec­u­lar (or frag­ment) ions by the ECR plas­ma. In this work­shop, we will re­port the com­pact ECRISs by a per­ma­nent mag­net type for the an­a­lyt­i­cal sys­tem.  
poster icon Poster MOPOT003 [3.320 MB]