Paper |
Title |
Page |
MOCOCK01 |
PK-ISIS: a New Superconducting ECR Ion Source at Pantechnik |
26 |
|
- A.C.C. Villari, C. Bieth, W. Bougy, B.N. Brionne, X. Donzel, G. Gaubert, R. Leroy, A. Sineau, O. Tasset, C. Vallerand
PANTECHNIK, BAYEUX, France
- T. Thuillier
LPSC, Grenoble, France
|
|
|
The new ECR ion source PK-ISIS was recently commissioned at Pantechnik. Three superconducting coils generate the axial magnetic field configuration while the radial magnetic field is done with multi-layer permanent magnets. Special care was devoted in the design of the hexapolar structure, allowing a maximum magnetic field of 1.32 T at the wall of the 82 mm diameter plasma chamber. The three superconducting coils using Low Temperature Superconducting wires are cooled by a single double stage cryo-cooler (4.2 K). Cryogen-free technology is used, providing reliability, easy maintenance at low cost. The maximum installed RF power (18.0 GHz) is of 2 kW. Metallic beams can be produced with an oven (Tmax = 1400 °C) installed with an angle of 5° with respect to the source axis or a sputtering system, mounted in the axis of the source. The beam extraction system is constituted of three electrodes in accel-decel configuration. Description of the source and results of the magnetic measurements will be given. Performances of the source in terms of beam intensities and charge states distribution will be presented.
|
|
|
Slides MOCOCK01 [3.226 MB]
|
|
|
TUPOT004 |
Microgan ECR Ion Source in a Van de Graaff Accelerator Terminal |
120 |
|
- G. Gaubert, C. Bieth, W. Bougy, B.N. Brionne, X. Donzel, A. Sineau, O. Tasset, C. Vallerand, A.C.C. Villari
PANTECHNIK, BAYEUX, France
- C. Chavez-de-Jesus, T. Gamboni, W. Geerts, G. Giorginis, R. Jaime Tornin, G. Lövestam, W. Mondelaers
JRC/IRMM, Geel, Belgium
|
|
|
The Van de Graaff accelerator at IRMM works since many years providing proton, deuteron and helium beams for nuclear data measurements. The original ion source was of RF type with quartz bottle. This kind of source, as well known, needs regular maintenance for which the accelerator tank must be completely opened. The heavy usage at high currents of the IRMM accelerator necessitated an opening about once every month. Recently, the full permanent magnet Microgan ECR ion source from PANTECHNIK was installed into a new terminal platform together with a solid state amplifier of 50W, a dedicated dosing system for 4 gases (with respective gas bottles H2, D2, He and Ar), and a set of dedicated power supplies and electronic devices for the remote tuning of the source. The new system shows a very stable behavior of the produced beam allowing running the Van de Graff without maintenance for several months. This contribution will describe the full installed system in details (working at high pressure in the terminal, spark effects and optic of the extraction).
|
|
|
Poster TUPOT004 [1.715 MB]
|
|
|