Paper |
Title |
Page |
MOPOT010 |
The Light Ion Guide CB-ECRIS Project at the Texas A&M University Cyclotron Institute |
55 |
|
- G. Tabacaru
Texas A&M University, Cyclotron Institute, College Station, USA
- J. Ärje
JYFL, Jyväskylä, Finland
- D.P. May
Texas A&M University Cyclotron Institute, College Station, Texas, USA
|
|
|
Texas A&M is currently configuring a scheme for the production of radioactive-ion beams that incorporates a light-ion guide (LIG) coupled with an ECRIS constructed for charge-boosting (CB-ECRIS). This scheme is part of an upgrade to the Cyclotron Institute and is intended to produce radioactive beams suitable for injection into the K500 superconducting cyclotron. The principle of operation is the following: a primary beam from the K150 cyclotron interacts with a production target placed in the gas cell. A continuous flow of helium gas maintains a constant pressure of 500 mbar maximum in the cell. Recoils are thermalized in the helium buffer gas and ejected from the cell within the gas flow through a small exit hole. The positively charged recoil ions (1+) are guided into a 2.5 m long, rf-only hexapole and will be transported in this manner on-axis into the CB-ECRIS. The CB-ECRIS operates at 14.5 GHz and has been specially constructed by Scientific Solutions of San Diego, California for charge-boosting. An overview of the entire project will be presented with details on different construction phases. Specific measurements and results will be presented as well as future development plans.
|
|
|
Poster MOPOT010 [12.413 MB]
|
|
|
TUPOT010 |
Effects of Microwave Frequency Fine Tuning on the Performance of JYFL 14 GHz ECRIS |
137 |
|
- V.A. Toivanen, V.P. Aho, J. Ärje, P. Jones, J.A. Kauppinen, H. A. Koivisto, P. Peura, O.A. Tarvainen
JYFL, Jyväskylä, Finland
- L. Celona, G. Ciavola, S. Gammino
INFN/LNS, Catania, Italy
- A. Galatà
INFN/LNL, Legnaro (PD), Italy
- D. Mascali
CSFNSM, Catania, Italy
- T. Ropponen
NSCL, East Lansing, Michigan, USA
|
|
|
Measurements have been carried out at Department of Physics, University of Jyväskylä (JYFL) to study the effects of microwave frequency fine tuning on the performance of JYFL 14 GHz electron cyclotron resonance ion source. The frequency was varied within an 85 MHz band around the normal operation frequency of 14.085 GHz. The radial bremsstrahlung emission was measured for plasma diagnostics purposes and mass separated ion beam currents extracted from the ion source were recorded at the same time. Also, beam quality studies were conducted by measuring the ion beam emittance and shape with and without enhanced space charge compensation. The obtained results are presented and possible origins of seen phenomena in measured quantities are discussed.
|
|
|
Poster TUPOT010 [0.678 MB]
|
|
|