Paper |
Title |
Page |
TUPD32 |
THz Radiation Diagnostics for Monitoring the Bunch Compression at the SwissFEL Injector Test Facility |
374 |
|
- C. Gerth, B. Schmidt, S. Wesch
DESY, Hamburg, Germany
- R. Ischebeck, G.L. Orlandi, P. Peier, V. Schlott
PSI, Villigen, Switzerland
|
|
|
At the SwissFEL Injector Test Facility, installation of a magnetic chicane for longitudinal bunch compression is foreseen for the first half of 2011. Bunch compression will be accomplished by operating two S-band accelerating structures on-crest and two S-band structures at off-crest RF phases. An X-band structure for the linearization of the longitudinal phase space will be installed at a later stage. The detection of coherent synchrotron radiation or coherent diffraction radiation in the THz range can be used to monitor the bunch compression process and stabilize the RF phases by a beam-based feedback. In this paper, we study the source characteristics of the edge radiation emitted at the 4th dipole of the bunch compressor as well as the diffraction radiation generated by a metallic foil with a hole. Particle tracking simulations were used to model the bunch compression process for different operation modes. The performance of a bunch compression monitor consisting of focusing mirrors and band pass filters has been evaluated by simulating the THz radiation transport of the optical components.
|
|
|
TUPD33 |
Coherent Resonant Diffraction Radiation from Inclined Grating as a Tool for Bunch Length Diagnostics |
377 |
|
- L.G. Sukhikh, G. Kube
DESY, Hamburg, Germany
- A. Potylitsyn
Tomsk Polytechnic University, Tomsk, Russia
- V. Schlott
PSI, Villigen, Switzerland
|
|
|
There exists considerable interest in studying new types of non-invasive bunch length diagnostics for sub-picosecond bunches. In this context coherent Smith-Purcell radiation (CSPR) is a good candidate because the use of grating causes wavelength dispersive radiation emission, i.e. a CSPR based monitor does not require any additional spectrometer. In contrast to existing CSPR monitors a new scheme is proposed with two detectors placed at fixed positions, and a wavelength scan is performed by scanning the tilt angle between grating surface and beam axis. In this scheme the information of both detectors, positioned opposite to each other and perpendicular to the beam axis, can be combined by taking the intensity ratio of the signals from both detectors. The advantage of such diagnostics scheme is that one has not to rely on absolute values of the radiation yield, avoiding the need to know the sensitivity of each detector with high accuracy. In contrast to CSPR which is emitted from a grating oriented parallel to the beam, the effect is termed coherent resonant diffraction radiation when the grating is tilted. In the report we present simulation results and detailed experimental plan.
|
|
|