Author: Petri, P.
Paper Title Page
MOPD27 A Sensitive Resonant Schottky Pick-Up for the ESR Storage Ring at GSI 107
 
  • F. Nolden, P. Hülsmann, P. Moritz, C. Peschke, P. Petri, M. Steck, H. Weick
    GSI, Darmstadt, Germany
  • Yu.A. Litvinov
    MPI-K, Heidelberg, Germany
  • M.S. Sanjari
    IKF, Frankfurt am Main, Germany
  • J.X. Wu, Y.D. Zang, S.H. Zhang, T.C. Zhao
    IMP, Lanzhou, People's Republic of China
 
  A cavity-like Schottky detector for the heavy ion storage ring ESR at GSI is presented. It works at resonant frequencies around 245 MHz, its loaded Q value is 511, and its loaded R/Q value is roughly 55 Ohms. It features both a very good sensitivity even for beams with single circulating ions and the possibility to take valuable spectra in short time. A few experiments with the new device are presented which show clearly that the device offers new experimental opportunities, both for accelerator diagnostics and nuclear physics experiments. A similar device will be built into the CSRe storage ring at IMP.