Author: Michalek, B.
Paper Title Page
TUPD43 XFEL Beam Loss Monitor System 401
 
  • A. Kaukher, I. Krouptchenkov, B. Michalek, D. Nölle, H. Tiessen
    DESY, Hamburg, Germany
 
  European XFEL will have a sophisticated Machine Protection System, part of which - Beam Loss Monitors(BLM). The monitors will detect losses of electron beam, in order to protect the components of the XFEL from damage and excessive activation. For protection of undulators, BLMs with a scintillator bar will be used. BLMs at places with high radiation load will be equipped with fused silica rods. Beam dumps of the XFEL will be instrumented with glass-fiber BLMs. The BLMs were tested with an electron test-beam at DESY, as well as at FLASH. Due to large amount of light produced by scintillator and high gain of the used photomultiplier, no optical grease is needed in front of the photomultiplier' window, while typical cathode voltage is only 500-600 volt. The prototype with quartz glass was typically operated at higher cathode voltage. Good operation of all three types of BLMs prototypes was obtained. It is planned to use same monitors also for the FLASH2 project. Current status of the XFEL BLM system development will be presented.