TUPD21 Frontend Measurements and Optimizations at Libera Brilliance BPM Electronics during Commissioning of the Petra III Synchrotron Light Source 350
 
  • F. Schmidt-Föhre, G. Kube, J.M. Maass, K. Wittenburg
    DESY, Hamburg, Germany
 
  New 3rd generation synchrotron light sources like Petra III utilize high-accuracy beam position measurement (BPM) systems to achieve the desired precision for beam position measurement and control, as needed for electron/positron beam stability and brilliance of the delivered photon beam. To reach the design goals, specifically adapted and parameterized commercial-of-the-shelf (COTS) Libera Brilliance BPM processor electronics are used within the Petra III BPM system. Quality of the acquired position measurement and orbit control data is highly dependent on the properties and setup of the analog and digital frontend of such BPM electronics. This paper shows influences and optimizations at the BPM system frontend of the Petra III light-source in reference to corresponding measurements done during the accelerator commissioning phase.