Author: Kiupel, G.
Paper Title Page
TUPD96 Fast and Critical Detection Devices Planned for the Machine Protection System at the Facility for Rare Isotope Beams 533
 
  • G. Kiupel, S. Assadi, T.D. Brown, P. Chu, J.L. Crisp, S. Peng, M.W. Stettler, Y. Zhang
    FRIB, East Lansing, Michigan, USA
 
  Funding: Work supported by US DOE Cooperative Agreement DE-SC0000661
The Facility for Rare Isotope Beams (FRIB) at Michigan State University (MSU) will use a 400 kW, heavy-ion cw linac to produce rare isotopes in support of a rich program of fundamental research. In the event of operational failures, the Machine Protection System (MPS) shuts off the beam within microseconds to control beam losses that may damage accelerator components. The operational mode is distributed to all fast and critical devices that have multiple hardware checkpoints and comparators. A relational database provides the framework for the development of the MPS management application. In this paper, we present the FRIB MPS architecture, plans and implementation.