Author: Igarashi, Z.
Paper Title Page
MOPD08 Beam Diagnostics in the J-PARC Linac for ACS Upgrade 50
 
  • A. Miura, S. Sato
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken, Japan
  • Z. Igarashi, M. Ikegami, T. Miyao, T. Toyama
    KEK, Ibaraki, Japan
  • T. Tomisawa
    JAEA/LINAC, Ibaraki-ken, Japan
 
  J-PARC had developed the beam diagnostic devices for the current J-PARC linac and has used them since the operation start. J-PARC linac began the energy upgrade project since 2009 and 21 ACS cavities will be installed. In this project, many cavities and related devices are newly installed in the ACS section and its downstream part. Because the beam parameters are updated, new beam diagnostic devices are fabricated and current diagnostic devices are developed. Beam position monitors (BPM) are newly designed and fabricated, based on the computer simulation and bench test. Because the gas proportional BLMs as the current BLM are sensitive to background noise of X-ray emitted from RF cavities, it is difficult to recognize real beam loss. We need to subtract an X-ray noise from the signal from BLM, another candidate BLMs have been tried to measure the beam loss. In addition, the bunch shape monitor for the longitudinal tuning has been developed in the corroboration with the institute for nuclear research, Russia. In this paper, we describe the new developed devices and their development process, especially for beam loss monitor and the developing bunch shape monitor.  
 
MOPD43 Beam Loss Detected by Scintillation Monitor 149
 
  • A. Miura, T. Maruta
    JAEA/J-PARC, Tokai-mura, Japan
  • K. Hasegawa, N. Ouchi, H. Sako
    JAEA, Ibaraki-ken, Japan
  • Z. Igarashi, M. Ikegami, T. Miyao
    KEK, Ibaraki, Japan
 
  Ar gas proportional BLMs have measured the beam loss through operations, but they are also sensitive to background noise of X-ray emitted from RF cavities. We have tried to measure the beam loss using scintillation monitors which would bring more accurate beam loss measurements with suppression of X-ray noise. We measured beam loss using scintillation beam loss monitors. Because this scintillation BLM is sensitive for low energy gamma-rays and fast neutrons, small signals from X-rays would be also detected. As the measurement results, a good signal to noise ratio is observed for the scintillation monitor with quite low sensitivity to the background X-ray. And many single events are observed in the intermediate pulse bunch with about 600 ns as pulse width. After all signals passed through the filter circuit and integrated circuit, total amount of X-ray noise can become smaller. We obtained the good performances of scintillation BLM with small effect of X-ray noise. This monitor can be used for beam loss measurement and a knob for tuning. Furthermore, because the detail structure can be detected, this monitor could be employed for another diagnostic device.  
 
TUPD18 Beam Position Monitors for the ACS Section of the J-PARC Linac 341
 
  • T. Miyao, Z. Igarashi, T. Toyama
    KEK, Ibaraki, Japan
  • A. Miura
    JAEA/J-PARC, Tokai-mura, Japan
 
  The J-PARC is consisted of Linac, 3GeV-RCS, and 50GeV-MR. We are aiming at the energy upgrade of J-PARC linac from 181MeV to 400MeV. We employed the ACS(Annular Coupled Structure) as the acceleration cavities. To have the energy upgrade, we need to develop beam instruments including beam position monitors (BPMs). Then, we designed them to be able to measure a horizontal and vertical beam position and employed a stripline-type as their electrodes. The BPMs are required to be calibrated to the accuracy of beam orbit within 100μm. To achieve the requirement, we did some calibrations. First, we decided a width of stripuline, whose characteristic impedance can be calibrated to 50 Ω with electric field simulations. Second, we also measured characteristic impedance of 4 different striplines per a BPM corresponding with BPM simulations. Last, we measured an electrical center position of BPMs with a simulated beam signal at 324MHz, 6dBm. A BPM will be installed at each quadrupole magnet in the ACS section to be used for a beam commissioning. Systematic calibration of developed BPMs is described in this paper. In addition, a phase measurement using these BPMs will be considered.