Paper | Title | Page |
---|---|---|
MOPD85 | Beam Emittance Studies at the Heavy Ion Linac UNILAC | 245 |
|
||
New accelerating structures for the UNILAC at GSI were commissioned in the last two years [1, 2], and major machine upgrades in order to meet the requirements for FAIR are in preparation [3, 4]. Beam emittance is one of the key beam parameters that are essential for any beam dynamics calculation, for the design of new accelerators as well as verification or investigation of existing machines. Its measurement is intricate and often time consuming. Extensive emittance measurements went along with the commissionings and were conducted to provide a reliable basis for beam dynamics simulations. In addition to the 10 permanent transverse emittance measurement devices installed all over the UNILAC, two "mobile" devices had been built and mounted at four different sites in the UNILAC. This work shows the standard slid-grid device used for transverse beam emittance measurements and gives an overview of the activities and results. The following topics will be presented with respect to design studies and simulations: Emittance growth of high current ion beams along the UNILAC, stripping, and resonance effects.
[1] H. Vormann et al., LINAC10, MOP040 [2] P. Gerhard et al., IPAC10, MOPD028 [3] W. Barth et al., PAC09, FR5REP059 [4] S. Mickat et al., LINAC10, MOP042 |
||
![]() |
Poster MOPD85 [10.077 MB] | |