TUPD16 High Frequency Measurements of the Beam Position Monitors for the TBL Line of the CTF3 at CERN 335
 
  • J.J. García-Garrigós, C. Blanch Gutierrez, J.V. Civera-Navarrete, A. Faus-Golfe
    IFIC, Valencia, Spain
  • B. Gimeno
    UVEG, Burjasot (Valencia), Spain
 
  Funding: Funding Agency: FPA2010-21456-C02-00
A series of Inductive Pick-Ups (IPU) for Beam Position Monitoring (BPM) with its associated electronics were designed, constructed and tested at IFIC. A full set of 16 BPMs, so called BPS units, were successfully installed in the Test Beam Line (TBL) of the 3rd CLIC Test Facility (CTF3) at CERN. Two different characterization tests, at low and high frequencies, were carried out on the BPS units: The low frequency test, in the beam pulse time scale (until 10ns/100MHz), determined the BPSs parameters directly related to the beam position monitoring and the high frequency test, reaching the microwave X-Ku bands around the beam bunching time scale (83ps/12GHz). In this paper we describe the results and methods used to obtain the longitudinal impedance in the frequency range of interest. This test is based on the S-parameters measurements of the propagating TEM mode in a matched coaxial waveguide, specifically designed for the BPS, which is able to emulate an ultra-relativistic electron beam.
 