Paper |
Title |
Page |
MOPD23 |
Photon BPM Electronics Development at Taiwan Light Source |
95 |
|
- P.C. Chiu, J. Chen, Y.K. Chen, K.T. Hsu, K.H. Hu, C.H. Kuo
NSRRC, Hsinchu, Taiwan
|
|
|
Photon BPMs are very useful for photon beam position and stability observation. There are several kinds of photon BPMs and electronics with different design installed at beamline front-ends at the Taiwan Light Source. To provide a better integration and efficient usage of the photon BPM, a commercial BPM electronics - Libera Photon was chosen for an integral solution and has showed at least one micron performance for several months of testing. In this report, the installation process and testing results of the photon BPM will be presented.
|
|
|
Poster MOPD23 [0.595 MB]
|
|
|
TUPD23 |
New Bunch-by-Bunch Feedback System for the TLS |
353 |
|
- C.H. Kuo, Y.K. Chen, Y.-S. Cheng, P.C. Chiu, K.T. Hsu, K.H. Hu
NSRRC, Hsinchu, Taiwan
|
|
|
FPGA based bunch-by-bunch feedback systems were deployed in 2005-2006 by using SPring-8 designed feedback processors for the Taiwan Light Source. To provide spare units and explore integrate with the control system in the EPICS toolkit environment, feedback processors from the Dimtel were setup. The new system can be swap with the existed system by simple cable re-connection and integrated with the EPICS system in seamless way. Rich functionality except the basic feedback function includes excitation of individual bunch or specifies bunches, averaged spectrum, tune measurement by the feedback dip in the averaged spectrum, fill pattern measurement,
etc. are explorer. Current stage implementation and features of the system will summary in this report.
|
|
|
TUPD67 |
Injection Efficiency Diagnostic at TLS Storage Ring |
461 |
|
- P.C. Chiu, J. Chen, Y.K. Chen, K.T. Hsu, K.H. Hu, C.H. Kuo
NSRRC, Hsinchu, Taiwan
|
|
|
TLS is now running at 360 mA top-up mode. In the normal situation, it takes few minutes for injection from zero current to 360 mA. When the working point is drifted too much at machine start, however, injection efficiency become worsen and it is necessary to adjust some machine parameters such as quadrupole strength, transport line correctors or booster dipole to improve efficiency. The current reading at 10 Hz time resolution which is the same with injection cycle seems too rough to estimate efficiency therefore a new diagnostic tool based on BPM sum reading is developed to provide 10 kHz waveform display every second. Operators could utilize it to estimate efficiency more precise, quickly and easier.
|
|
|
Poster TUPD67 [0.842 MB]
|
|
|
TUPD76 |
Vibration and Beam Motion Diagnostics in TLS |
485 |
|
- Y.K. Chen, J. Chen, P.C. Chiu, K.T. Hsu, K.H. Hu, C.H. Kuo
NSRRC, Hsinchu, Taiwan
|
|
|
High beam stability is essential in a modern synchrotron light source due to small emittance. Beam motion caused by various factors should be remedy by various approaches to achieve high beam stability. Vibration will deteriorate beam stability and need considered as a part of beam diagnostic. An integrated environment for beam orbit and vibration monitoring systems were set up for various studies. Implementation details and some beam observation will be presented in this report.
|
|
|
Poster TUPD76 [2.750 MB]
|
|
|