Review of Recent Upgrades & Modernizations on Diagnostics in the ESRF Storage Ring and Injector |
263 |
|
- B. Joly, P. Arnoux, D. Robinson, K.B. Scheidt
ESRF, Grenoble, France
|
|
|
Over the last two years a number of upgrades and modernizations have been implemented on diagnostic tools in both the Injector system and the Storage Ring. Brand new diagnostic tools have also been added. In the Injector, a new Transfer Line current monitor has been installed, as well as four new ¼ λ Striplines equipped with Single-Pass Libera electronics. In the Storage Ring, a new Visible Light Mirror (VLM) system has replaced the original system that had been in place for more than 15 years. Also, the acquisition system for the DC Current Transformers has been upgraded with new hardware. Descriptions and results are presented on the improved reliability, sensitivity and resolution of these systems.
|
|
|