TUPSM050 Studies of APS Storage Ring Vacuum Chamber Thermal Mechanical Effects and their Impact on Beam Stability 265
 
  • R.M. Lill, J.T. Collins, G. Decker, L. Erwin, J.Z. Xu, B.X. Yang
    ANL, Argonne
 
 

As the Advanced Photon Source (APS) prepares for a large-scale upgrade, many of the fundamental limitations on beam stability have to be identified. Studies have been conducted to measure thermal mechanical effects of both the water and air handling systems impacting insertion device vacuum chambers (IDVES). Mechanical stability of beam position monitor pickup electrodes mounted on these small-gap IDVES places a fundamental limitation on long-term x-ray beam stability for insertion device beamlines. Experiments have been conducted on an ID vacuum chamber indicating that the BPM blocks are moving with water temperature cycles at the level of 10 microns/degree C. Measurements and potential engineering solutions will be described.