TUPSM010 Residual-Gas-Ionization Beam Profile Monitors in RHIC 116
 
  • R. Connolly, J.M. Fite, S. Jao, S. Tepikian, C. Trabocchi
    BNL, Upton, Long Island, New York
 
 

Four ionization profile monitors (IPMs) in RHIC measure vertical and horizontal beam profiles in the two rings. These work by measuring the distribution of electrons produced by beam ionization of residual gas. In 2007 a prototype of a new design was installed in the yellow ring. During the 2007-2008 run it proved to be almost completely free from backgrounds from rf coupling, electron clouds and x-rays from upstream beam loss. In 2009 two more IPMs of this new design were installed and in the 2010 shutdown we will complete installation of four identical IPMs. This paper describes the new IPMs and shows data from the 2010 beam run. The new IPMs have been extremely important in the commissioning of the RHIC stochastic cooling system.