A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   R   S   T   U   V   W   X   Y   Z  

Taylor, M.A.

Paper Title Page
TUPSM014 LANSCE Harp Upgrade: Analysis, Design, Fabrication, and Installation 132
 
  • J.D. Gilpatrick, P. Chacon, M.E. Gruchalla, D. Martinez, J.F. Power, B.G. Smith, M.A. Taylor
    LANL, Los Alamos, New Mexico
 
 

The primary goal of this newly installed beam profile measurement is to provide the facility operators and physicists with a reliable horizontal and vertical projected beam distribution and location with respect to the proton beam target and beam aperture. During a 3000-hour annual run cycle, 5 microcoulombs of charge is delivered every 50 milliseconds through this harp to the downstream 1L target. The resulting radioactive annual dose near this harp is at least 600 MRads. Because of this harsh environment, the new harp design has been further optimized for robustness. For example, compared to an earlier design, this harp has half of the sensing wires and utilizes only a single bias plane. The sensing fibers consist of a 0.078-mm diameter SiC fiber. To hold these fibers to a rigid ceramic structure, a “collet” fiber-clamping device accomplishes the three goals of maintaining a mechanical fiber clamp, holding the sense fiber under a slight tensile force, and providing a sensing fiber electrical connection. This paper describes the harp analysis and design, and provides fabrication, assembly, and installation information, and shows how facility wiring was altered.