A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   R   S   T   U   V   W   X   Y   Z  

Staykov, L.

Paper Title Page
TUPSM057 Emittance Measurement Wizard at PITZ 282
 
  • A. Shapovalov
    MEPhI, Moscow
  • L. Staykov
    DESY Zeuthen, Zeuthen
 
 

The Photo Injector Test Facility at DESY, Zeuthen site (PITZ) develops electron sources of high brightness beams, required for linac based free electron lasers (FELs) like FLASH or the European XFEL. One of the key issues in electron beam optimization is the minimization of the transverse emittance. The main method to measure emittance at PITZ is a single slit scan technique, implying local beam divergence measurement by insertion of the slit mask at a definite location within the beam and measurements of the transmitted beamlet profile downstream of the slit station. “Emittance Measurement Wizard” (EMWiz) is the program used by PITZ operators for automated emittance measurements. EMWiz combines an acquisition program for beam and beamlet image recording and a postprocessing tool for the analysis of the measured transverse phase space of the electron beam. It provides a way to execute the difficult emittance measurements in an automatic mode and to get a calculated emittance result.