TUPSM108 Slow Orbit Feedback at RHIC 469
 
  • V. Ptitsyn, A. Marusic, R.J. Michnoff, M.G. Minty, G. Robert-Demolaize, T. Satogata
    BNL, Upton, Long Island, New York
 
 

Slow variations of the RHIC closed orbit have been strongly influenced by diurnal variations. These variations affect the reproducibility of RHIC operation and might have contributed to proton beam polarization degradation during past polarized proton runs. We have developed and commissioned a slow orbit feedback system in RHIC Run-10 to diminish these variations and improve energy ramp commissioning and tuning efficiency. This orbit feedback uses multiple dipole correctors and orbit data from an existing beam position monitor system. The precision of the orbit feedback system has resulted directly from application of an improved algorithm for measurement of the average orbit, from improved survey offsets and various measures taken to ensure deterministic delivery of the BPM data. Closed orbit corrections are calculated with an online model-based SVD algorithm, and applied by a control loop operating at up to 1 Hz rate. We report on the feedback design and implementation, and commissioning and operational experience in RHIC Run-10.