A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   R   S   T   U   V   W   X   Y   Z  

Nayak, S.

Paper Title Page
TUPSM011 Beam-Energy and Laser Beam-Profile Monitor at the BNL Linac 119
 
  • R. Connolly, B. Briscoe, C. Degen, W. Meng, R.J. Michnoff, M.G. Minty, S. Nayak, D. Raparia, T. Russo
    BNL, Upton, Long Island, New York
 
 

A beam profile and energy monitor for H- beams which measures electrons stripped from the beam by a laser has been installed in the high energy beam transport (HEBT) line at the Brookhaven National Lab linac. Our 100mJ/pulse, Q-switched laser neutralizes 70% of the beam during its 10ns pulse. Also electrons are stripped by the residual gas at a rate of ~1.5 x 10-8/cm at 1 x 10-7torr. Beam electrons have the same velocity as the beam and so have an energy of 1/1836 of the beam protons. There is a chamber in which the laser light passes through the ion beam followed by a dipole magnet which deflects the electrons by 90° through a biased retarding grid (V<125kV) into a Faraday cup detector. To measure beam profiles, a narrow laser beam is stepped across the ion beam removing electrons from the portion of the H- beam intercepted by the laser. To measure the energy spectrum of the electrons, we use either the gas-stripped or laser-stripped signal. The total current is measured as the voltage on the grid is raised in small steps. We deduce the energy spread of the H- beam by deconvolving the electron spectrum into components from beam energy and from space-charge fields.