A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Sugimoto, M.

Paper Title Page
TUPP013 Synchronized Data Distribution and Acquisition System Using Reflective Memory for J-PARC 3GeV RCS 1553
 
  • H. Takahashi, N. Hayashi
    JAEA/J-PARC, Tokai-Mura, Naka-Gun, Ibaraki-Ken
  • M. Sugimoto
    Mitsubishi Electric Control Software Corp, Kobe
 
  J-PARC 3GeV RCS inject the different parameter beam to each facilities, which are MLF and MR. Therefore, 3GeV RCS Control System must realize the monitoring and the operation that are distinguished "MLF beam" from "MR beam". And, we have developed the data distribution and acquisition system for "synchronized data" which required the distinguished monitoring and operation. We have designed and developed distribution and acquisition system using Reflective Memory (RM) for BPM data, which is one of synchronized data. There are 54 BPM, and BPM signal is processed by each BPM signal circuit (total 54 circuits). Then, we have designed that RM have 54 virtual ring memories and for a few seconds BPM data pre one virtual ring memory is buffered. And we decide BPM data is written virtual ring memory position based on "beam tag", which distributed from RM of J-PARC Timing System. This "beam tag" is synchronized across J-PARC. Thereby, 54 BPM data that written same virtual ring memory position become BPM data for identical beam. The paper presents the current status of the synchronized data distribution and acquisition system using RM.