A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Koeth, T. W.

Paper Title Page
THPC013 Start to End Simulations of Transverse to Longitudinal Emittance Exchange at the A0 Photoinjector 3002
 
  • R. P. Fliller, H. T. Edwards, J. Ruan
    Fermilab, Batavia, Illinois
  • T. W. Koeth
    Rutgers University, The State University of New Jersey, Piscataway, New Jersey
 
  Various schemes to exchange the transverse and longitudinal emittance have been proposed (Cornacchia and Emma, Kim et.al). One scheme involves a deflecting mode RF cavity between two doglegs to exchange the horizontal and longitudinal emittances. This will produce a complete and uncoupled emittance exchange in the thin cavity limit using first order matrix optics. Various other effects, such as a finite length cavity, can leave the emittances coupled after the exchange and dilute the final emittances. Other effects such as space charge and synchrotron radiation can only be investigated through simulations. An exchange experiment is underway at the A0 Photoinjector at Fermilab. In this paper we present start to end simulations of the experiment using various codes to account for space charge and Coherent Synchrotron Radiation effects. Astra is used to simulate all of the straight sections, including the deflecting mode RF cavity. CSR track simulates the doglegs, and the spectrometer. The results of these simulations are compared with analytical approximations and preliminary data. The effect on the exchange is also discussed.  
THPC014 Investigation of Possible CSR Induced Energy Spread Effects with the A0 Photoinjector Bunch Compressor 3005
 
  • R. P. Fliller, H. T. Edwards, G. M. Kazakevich, J. Ruan, R. Thurman-Keup
    Fermilab, Batavia, Illinois
  • T. W. Koeth
    Rutgers University, The State University of New Jersey, Piscataway, New Jersey
 
  The bunch compressor of the A0 Photoinjector at Fermilab was removed this past spring to install a transverse to longitudinal emittance exchange experiment. Prior to its removal questions arose about the possibility of observing the effects of Coherent Synchrotron Radiation on the compressed beam. The energy spread of the beam with and without compression was measured to observe any changes. Various beam charges were used to look for square law effects associated with CSR. No direct observation of CSR was attempted because the design of the vacuum chamber did not allow it. In this paper we report the results of these experiments and comparison with simulations using ASTRA and CSRTrack. The results are compared with analytical approximations. The implications for the ongoing transverse to longitudinal emittance exchange experiment are discussed.  
THPC020 Emittance Exchange at the Fermilab A0 Photoinjector 3020
 
  • T. W. Koeth
    Rutgers University, The State University of New Jersey, Piscataway, New Jersey
  • L. Bellantoni, H. T. Edwards, R. P. Fliller, A. H. Lumpkin, J. Ruan
    Fermilab, Batavia, Illinois
 
  A transverse to longitudinal emittance exchange experiment is underway at the A0 Photoinjector at Fermilab. Our scheme employs a TM110 deflecting mode RF cavity between two magnetic doglegs proposed by Kim et. al. The beamline has been installed, characterization of the beamline is complete and data taking has begun. In this paper we report on efforts to date to observe the transverse to longitudinal emittance exchange. Measurements will be compared to analytical predictions and simulations.