A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Yamamoto, K.

Paper Title Page
TUPLT025 Matching of a C6+ Ion Beam from a Laser Ion Source to a RFQ 1195
 
  • R. Becker, R.A. Jameson, A. Schempp
    IAP, Frankfurt-am-Main
  • T. Hattori
    RIKEN, Saitama
  • N. Hayashizaki, H. Kashiwagi
    RLNR, Tokyo
  • M. Okamura
    RIKEN/RARF/CC, Saitama
  • K. Yamamoto
    RIKEN/RARF/BPEL, Saitama
 
  A laser ion source, driven by a Nd-YAG laser can provide more than 100 mA of C6+ ions for a duration of about 1 μs, which is well matching the task of single-turn injection into synchrotrons for hadron tumor therapy with light ions. The ?direct? injection scheme has been improved by providing a design, which reduces the surface field strength to less than 30 kV/cm on all critical parts on relative negative potential. The new design keeps the advantage of divergent ion emission and acceleration, which seems to be the only way to keep the surface fields in limits, but includes a decelerating electrostatic lens on birth potential of the ions to refocus the emerging ion beam to the RFQ entrance. The whole design is very compact and allows for electrostatic steering between the ion source and the RFQ.  
TUPLT024 A Comparison of High Current Ion Beam Matching from an Ion Source to a RFQ by Electrostatic and by Magnetic Lenses 1192
 
  • R. Becker, R.A. Jameson, A. Schempp
    IAP, Frankfurt-am-Main
  • T. Hata, N. Hayashizaki, H. Kashiwagi, K. Yamamoto
    RLNR, Tokyo
  • T. Hattori, M. Okamura, A. Sakumi
    RIKEN, Saitama
 
  In order to improve the ?direct? injection scheme of the Riken Nd-YAK-laser driven ion source into a RFQ rf-accelerator, several basic methods have been investigated and compared, in order to transform the initially divergent ion beam into a convergent one, needed for matching the high current (100 mA C6+) ion beam at an energy of 100 keV to a RFQ. From the point of power supplies and break down characteristics, the simplest solution is a decelerating electrostatic lens, with the decelerating electrode operated on ion source potential. Due to the strong divergence of the ions beam after acceleration, this lens will be filled to an aperture, which causes strong aberrations. Therefore, we also investigated to use an accelerating potential on the lens electrode. This reduces significantly the filling of the lens and the emittance growth is only a factor of 3, as compared to the decelerating lens with a factor of 30! Finally we have been looking also into a magnetic matching system, which can match the ion beam to the RFQ with virtually no emittance growth.  
THPLT079 The Study of APF-IH Linac 2676
 
  • K. Yamamoto, T. Hattori, K. Yamamoto
    RLNR, Tokyo
  • M. Okamura
    RIKEN, Saitama
  • S. Yamada
    NIRS, Chiba-shi
 
  We have manufactured the IH linac with Alternating Phase Focus as the test machine of medical accelerator injection. It will accelerate C4+ ion up to 2MeV/u from 40 keV/u, the tank length is around 1.5m, operation frequency is 100MHz. Furthermore, We have succeeded the acceleration test using proton with simple acceleration system consist of P.I.G. ion source, bending magnets and focus lenses, less than 5m long. Otherwise, We have been making the program of beam dynamics with the results of the electro-magnetic simulation soft (Micro-Wave-Studio,OPERA-3D), it has the merit of easily to calculate the 3D- beam dynamics in the tank. We will report the some results of the test and the beam simulation and the comparisons.  
THPLT079 The Study of APF-IH Linac 2676
 
  • K. Yamamoto, T. Hattori, K. Yamamoto
    RLNR, Tokyo
  • M. Okamura
    RIKEN, Saitama
  • S. Yamada
    NIRS, Chiba-shi
 
  We have manufactured the IH linac with Alternating Phase Focus as the test machine of medical accelerator injection. It will accelerate C4+ ion up to 2MeV/u from 40 keV/u, the tank length is around 1.5m, operation frequency is 100MHz. Furthermore, We have succeeded the acceleration test using proton with simple acceleration system consist of P.I.G. ion source, bending magnets and focus lenses, less than 5m long. Otherwise, We have been making the program of beam dynamics with the results of the electro-magnetic simulation soft (Micro-Wave-Studio,OPERA-3D), it has the merit of easily to calculate the 3D- beam dynamics in the tank. We will report the some results of the test and the beam simulation and the comparisons.