A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Tateishi, T.

Paper Title Page
THPKF038 Radiation Damage of Magnet Coils due to Synchrotron Radiation 2356
 
  • K. Tsumaki, S. Matsui, M. Oishi, T. Yorita
    JASRI/SPring-8, Hyogo
  • T. Shibata, T. Tateishi
    KOBELCO, Hyogo
 
  Radiation damage of the equipment in the SPring-8 storage ring tunnel has become a serious problem. In the storage ring, the unnecessary radiation from bending magnets is shielded by absorbers. The equipment around the absorbers was damaged by the scattered radiation from the absorbers. Last year, cooling water leaked from the rubber hose of magnets. It was due to the deterioration of rubber hose caused by synchrotron radiation. We measured the radiation distribution around the storage ring and found that the most high intensity spot was on the magnet coil near the absorbers. If the coils are damaged and the magnets do not work correctly, we need to shut down the storage ring to exchange the magnet coils. To avoid such a situation, we needed to clarify the relation between the radiation damage of the coils and the dose of radiation. We did an acceleration test of the radiation damage of magnet coils. The magnet coils were exposed to the radiation from the bending magnet directly. We observed the degree of damage with changing the doses of radiation. In this paper, we describe about these acceleration tests and test results.