A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Tanaka, M.

Paper Title Page
THPLT074 The Beam Loss Monitor System of the J-parc LINAC, 3 GEV RCS and 50 GEV MR 2664
 
  • S. Lee, T. Toyama
    KEK, Ibaraki
  • J. Kishiro
    JAERI/LINAC, Ibaraki-ken
  • M. Tanaka
    JAERI, Ibaraki-ken
 
  The high intensity beam accelerator complex itself requires the significant progress of design study and hardware R&D. Operational beam intensity should be limited by the beam loss and activation level of the equipment. Once the beam loss exceeds a criterion at outer environment, beam intensity has to be decreased to prevent the further activation. In order to investigate loss mechanism and suppress the beam loss, a beam loss monitor system have been developed for the J-PARC linac, 3 GeV RCS and 50GeV MR. The system will be essential component for beam commissioning, tuning and machine protection in high intensity beam accelerators. The loss monitor system is composed of scintillator, argon-methane/3He gas filled proportional counter and air filled coaxial cable ionization chamber, which detect g-ray, neutron and charged particles induced by lost particle. It is necessary to measure wide dynamic range of loss intensity for various beam energies. To prevent the activation and heat load by intense beam loss, fast time response of loss signals is required. In this paper, construction and application of loss monitor system are described in detail. Preliminary result of demonstration in the KEK-PS and calibration with cobalt 60 g-ray radiation source are also discussed.