MOPLT060 New RF Measuring System for Cavity Characterization 692
 
  • S. Stark, G. Bisoffi, l. Boscagli, V. Palmieri, A.M. Porcellato
    INFN/LNL, Legnaro, Padova
 
  New computer based mobile measuring system for laboratory and online characterization of superconducting cavities has been put into operation at LNL. The system covers the frequency range from 80 to 350 MHz and represents a reliable, fast and precise instrument for cavity testing. The list of automatic and semiautomatic procedures includes line calibrations, frequency sweep, decay time measurement, Q(Eacc) curve acquisition and pulse conditioning.  
TUPKF024 Operation Experience with ALPI Nb/Cu Resonators 1018
 
  • A.M. Porcellato, L. Bertazzo, M. De Lazzari, D. Giora, V. Palmieri, S. Stark, F. Stivanello
    INFN/LNL, Legnaro, Padova
 
  The refurbishing, by replacing the Pb superconducting film by Nb, of ALPI QW accelerating resonators was completed in 2003. All the 52 cavities are now in operation showing a large increase in the average accelerating field, which exceeds 4.5 MV/m (21 MV/m pick electrical surface field). The performance of renewed resonators has been increasing with time reaching 6MV/m in the last produced units. The increase in ALPI performance and the advantage in conditioning and setting time obtained by the upgrading process will be reported.