A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Sasabe, J.

Paper Title Page
MOPKF046 Photoelectron RF Gun Designed as a Single Cell Cavity 411
 
  • H. Dewa, T. Asaka, H. Hanaki, T. Kobayashi, A. Mizuno, S. Suzuki, T. Taniuchi, H. Tomizawa, K. Yanagida
    JASRI/SPring-8, Hyogo
  • J. Sasabe
    Hamamatsu Photonics K.K., Hamakita, Shizuoka
  • M. Uesaka
    UTNL, Ibaraki
 
  The paper describes the recent improvements of S-band RF-gun at SPring-8. The cavity of the gun is a single-cell pillbox, and the copper inner wall is used as a cathode. The electron beam from the cathode was accelerated up to 4.1 MeV at an electric field of 175 MV/m. For emittance compensation, two solenoid magnets were used. A 3m linac and a quadrupole scan emittance diagnostic were added after the RF-gun. The beam energy spread and beam emittance after the linac is presented. The beam emittance measured with quadrupole scan is compered to that measured with double slits just after the RF-gun. For high quantum efficiency, Cs2Te cathode was also tested. It is vacuum sealed in a cartridge-type electric tube and four tubes can be installed in a vacuum chamber behind the cavity. Although the quantum efficiency after RF conditioning for two hours to achieve 90MV/m was 3%, it decreased to 1% after the 28 hours RF conditioning.