THYLH01 Beam Diagnostics at the VUV-FEL Facility 262
 
  • J. Feldhaus, D. Noelle
    DESY, Hamburg
 
  The free electron laser (FEL) at the TESLA Test facility at DESY will be the first FEL user facility for VUV and soft X-ray radiation down to 6 nm wavelength, the commissioning starts in summer 2004. Commissioning as well as stable FEL operation require a combination of different diagnostic tools for measuring both electron and photon beam parameters, including the full phase space distribution of the bunch charge, exact timing with sub-picosecond resolution, electron and photon beam overlap along the undulator, radiation beam position in the user area 50-70 m behind the undulator, intensity and spectral distribution of the radiation pulses and others. Much effort has been put in the development of instrumentation for measuring the longitudinal bunch charge distribution, for controlling the electron beam orbit along the undulator, and for online monitoring the radiation intensity, position and spectral distribution. This contribution gives an overview of the complete electron and photon beam diagnostics of the FEL facility and focuses particularly on the instrumentation which is crucial or specific for the FEL operation.  