Paper | Title | Page |
---|---|---|
THPKF044 | The Improvement of NSRRC Linac for Top-up Mode Operation | 2371 |
|
||
The performance of the 50 MeV linac at the National Synchrotron Radiation Research Center (NSRRC) was examined and has been improved recently. The major improved items were 1) adopting a command-charging scheme to replace the resonance charging for the linac modulator; and 2) gun electronics. As a result, the beam quality was improved in terms of its energy spectrum and stability. The correlation between the improvement of beam quality and component upgrading is analyzed. The influence of the beam quality improvement to the recently proposed top-up mode operation in 2005 will also be discussed in this report. |