A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Jung, R.

Paper Title Page
WEPKF017 The 5 T Superconducting Undulator for the LHC Synchrotron Radiation Profile Monitor 1630
 
  • R. Maccaferri, M. Facchini, R. Jung, D. Tommasini, W.  Venturini Delsolaro
    CERN, Geneva
 
  A Synchrotron Radiation Profile Monitor will be used in the LHC to measure the beam profiles from the injection energy of 450 GeV to the nominal energy of 7 TeV. The radiation will be provided by a sequence of two separate magnets: a two-periods 5 T superconducting undulator and the beam separation dipole D3. After a short description of the profile monitor layout, the paper reviews the electromagnetic and mechanical design of the undulator, and reports on the fabrication and cold test results of a first half period prototype.Finally, for the LHC operation with lead ion beams,a proposal for a monitor sensitivity upgrade by using a 12 T. superconducting undulator is presented and discussed.